ASTM D6721 & Combustion Hydrolysis Fluorine in Coal
Brand KN
Product origin Dalian,China
Delivery time 30 DAYS AFTER RECEIVING FULL PAYMENT
Supply capacity 30 sets/month
The KN-6721Z Fully Automatic Fluoride and Chloride Ion Analyzer is premium Coal Testing Equipment. Strictly complying with ASTM D6721, it utilizes oxidative hydrolysis microcoulometry for precise total chlorine determination and combustion hydrolysis for fluorine analysis. It ensures high efficiency and reliable data for laboratories.
KN-6721Z Fully Automatic Fluoride and Chloride Ion Analyzer
Overview
The KN-6721Z Fully Automatic Fluoride and Chloride Ion Analyzer is designed for the determination of total chlorine and fluorine in coal. For chlorine determination, it references ASTM D6721 Standard Test Method for Determination of Chlorine in Coal by Oxidative Hydrolysis Microcoulometry, covering the determination of total chlorine in coal. For fluorine determination, it utilizes a high-temperature combustion hydrolysis method coupled with a fluoride ion selective electrode.
Features
1. Equipped with a 7-inch LCD touch screen. The temperature, sample feeding position, and sample feeding time are continuously displayed on the screen, providing a user-friendly interface and simple operation.
2. The operating program can be customized and edited according to user requirements.
3. The furnace temperature uses PID control for the furnace current, ensuring high temperature control accuracy and effectively extending the service life of the silicon carbide tube.
4. The spiral stainless steel sample feeding mechanism allows the sample feeding distance, sample feeding position, and sample feeding speed to be freely and independently set.
5. The heating rate can be freely adjusted for speed (fast or slow), and the instrument can be plugged directly into a power outlet for use.
6. Fully automatic sample feeding and discharging, automatic sealing of the rubber stopper, automatic opening of the rubber stopper, and automatic resetting of the rubber stopper.
7. The evaporation rate can be freely adjusted, providing stable steam generation and a long service life.
8. Equipped with imported high-precision digital electrodes to ensure the accuracy of the test.
9. Features of the Titration Section: Equipped with fully automatic titration software, compatible with the latest Windows 10 computer operating system. The titration solution can be set, and the titration speed can be freely set according to sample characteristics. Data results can be queried, exported, and uploaded. Both fluorine and chlorine can be automatically titrated and automatically calculated, with measurement results generated automatically.
Technical Parameters
1. Temperature measurement accuracy: 0.1℃;
2. Temperature control accuracy: 1100±1℃;
3. Heating time: Approximately 25 minutes to reach 1100±1℃;
4. Temperature setting range: 100℃—1200℃;
5. Potential resolution: 0.1mV;
6. Current opening setting range: 0-200;
7. Test method: High-temperature combustion hydrolysis method;
8. Precision: Fluorine measurement range: 10-2000 μg/g; Chlorine measurement range: 0.003%-45%;
9. Power supply: AC220V±10%, 50Hz;
10. Overall power: ≤3.5KW;
11. Overall weight: 60kg;
12. Titration system dimensions: 583*356*361 (mm);
13. Overall dimensions: 800mm* 550mm* 610mm.