The KN-6721 Automatic Fluoride and Chloride Ion Analyzer is a specialized Coal Testing Equipment. Compliant with ASTM D6721, it utilizes oxidative hydrolysis microcoulometry for precise total chlorine determination, and high-temperature combustion with an ion selective electrode for fluorine analysis. It ensures accurate, efficient testing for the coal industry.

ASTM D6721 Determination of Chlorine in Coal

KN-6721 Automatic Fluoride and Chloride Ion Analyzer

Overview

The KN-6721 Automatic Fluoride and Chloride Ion Analyzer is designed for the determination of total chlorine and fluorine in coal. For chlorine determination, it references ASTM D6721 Standard Test Method for Determination of Chlorine in Coal by Oxidative Hydrolysis Microcoulometry, covering the determination of total chlorine in coal. For fluorine determination, it utilizes a high-temperature combustion hydrolysis method coupled with a fluoride ion selective electrode.

Principle

The coal sample is mixed with a small amount of quartz sand and combusted and hydrolyzed at 1100°C in a mixed gas stream of oxygen and water vapor. Various forms of fluorides in the coal are converted into volatile fluorides, which enter the condensed water and dissolve quantitatively. The fluoride ion concentration in the sample solution is then determined using a fluoride ion selective electrode (indicator electrode) and a saturated calomel electrode (reference electrode) via the standard addition method, from which the total fluorine content in the coal is calculated.

Technical Parameters

1. Temperature Control Range

· Temperature Control Accuracy: 1100±2℃.

2. Heating Rate

· Heating Time: Approximately 25 minutes to reach 1100±2℃.

3. Temperature Setting Range

· Temperature Setting Range: 900℃—1200℃.

4. Test Method

· Test Method: High-temperature combustion hydrolysis method.

5. Power Supply

· Power Supply: AC 220V±10%, 50Hz (Operating Voltage: AC 220V±20%, 50Hz±10%).

6. Maximum Power

· Maximum Power: 3 kW.

7. Weight

· Weight: 38 kg.

8. Operating Environment

· Ambient Temperature: 0℃~40℃.

· Ambient Humidity: ≤85% RH.

9. Dimensions

· Instrument Dimensions: 440 x 380 x 390 (mm).

Configurations

NO.

Name

Quantity

1

High-Temperature Hydrolysis Furnace

1 unit

2

Oxygen Aspirator

1 set

3

Silicon Carbide Tube

1 piece

4

Adapter Tube

2 pcs

5

Condenser Tube

2 pcs

6

Anti-splash Bulb

30 pcs

7

Electric Furnace

1 pc

8

High-temperature Silicone Tubing

5 m

9

Sample Feeding Rod

2 pcs

10

High-temperature Rubber Stopper

4 pcs

11

Thermocouple

1 pc

12

Pinch Clamp

1 pc

13

Weighing Spoon

1 pc

14

Tweezers

1 pc

15

Porcelain Crucible (or Porcelain Boat)

10 pcs

16

Small Water Pump

1 pc

17

Stirrer

1 set

18

Stirring Bar

1 pc

19

200 mL Beaker

8 pcs

20

500 mL Beaker

2 pcs

21

1000 mL Volumetric Flask

3 pcs

22

1000 mL Amber Volumetric Flask

1 pc

23

250 mL Reagent Bottle

2 pcs

24

125 mL Dropping Bottle

3 pcs

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right