KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (RDE-AES)

KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (RDE-AES)

28-03-2024

    Wear metals and contaminants in a test specimen are evaporated and excited by a controlled arc discharge using the rotating disk technique. The radiant energies of selected analytical lines and one or more references are collected and stored by way of photomultiplier tubes, charge coupled devices or other suitable detectors. A raison is made of the emitted intensities of the elements in the test specimen against those measured with calibration standards. The concentrations of the elements present in the oil test specimen are calculated and displayed. They may also be entered into a data base for processing.


Advantage of our KN-6595

1、Equipped with scanner, be able to scan the bar code of the sample instead of inputing the corresponding sample information

2、 Due to the intergrated design of the shaft, no need to do the alignment if no faults (no displacement)

3、 Due to the wavelength differences, we equipped with two optical fibers, right one for measure the lithium, calcium and sodium, whith the left side is for measuring the rest elements

4、 Operator is also able to create the application base on the real demands by himself, no need to be authorized by the manufacturer

Main features

KN

Familiar Branded ICP

Spectro oil

MOA

Y-type optical fiber transmission—Double-layer multi-segment array device detection system, 500mm focal length optical grating, it has high resolution (Reciprocal of linear dispersion is 0.3~0.4 nm/mm) and full range detection performance (wavelength from 190nm to 900nm)

Single optical fiber transmission, Roland circle beam split, 400mm focal length optical grating, photomultiplier or double-layer CCD detection system

Roland circle and photomultiplier system

Be able to measure 24 kinds of elements simultaneously, detection channel is able to be added by the operator as wish

Be able to measure 15~31 kinds of elements detection channel is able to be added but needs to be paid for more detection channel

Be able to measure 21~31 kinds of elements, detection channel can not be added

Adopts 14000v bidirectional excitation high repetition rate spark light source technologywhich features high reliability and good repeatability

One-way excitation spark light source

One-way excitation spark light source

Adopts UV enhanced photometer to replace the UV CCD, low cost

High-cost detector

High-cost detector

 


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy