Total Organic Carbon Analyzer for Water Samples
Brand KN
Product origin Dalian,China
Delivery time deliver as soon as received payment
Supply capacity 10 SETS/MONTH
The apparatus can determine the total organic content of environmental water quality, including tap water, surface water, river and lake water, seawater, domestic sewage, and industrial wastewater. It can also determine the organic content of new energy battery materials, chemical products, and electroplating solutions to ensure product quality and quality control. The UV oxidation method can detect low-concentration organic water samples, such as drinking water, boiler water, and purified water. For laboratory research, it can be expanded with solid and total nitrogen/total sulfur modules to detect the content of organics, total nitrogen, and total sulfur in solid or liquid samples.
Total Organic Carbon Analyzer for Water Samples
Overview
The apparatus can determine the total organic content of environmental water quality, including tap water, surface water, river and lake water, seawater, domestic sewage, and industrial wastewater. It can also test organic content in new energy battery materials, chemical products and electroplating baths to support routine quality control. The UV oxidation mode works well for low-level organic water samples including drinking water, boiler feed water and purified water. For lab research needs, optional solid sampling, total nitrogen and total sulfur modules can be fitted, enabling organic, TN and TS measurement for both liquid and solid samples.
Features
1. Equipped with an eight-way valve to automatically realize acid addition, sample injection and dilution.
2. The main unit offers the flexibility of persulfate oxidation or high-temperature catalytic oxidation for total carbons measurement. Such an approach gives you more standard methods compliance.
3. The high-temperature catalytic furnace offers flexibility by allowing different catalysts to be adapted for different samples. It features a programmable temperature control system with the working temperature adjustable between 680 °C and 900 °C.
4. Heated and thermostatted inorganic-carbon reaction unit eliminates sample peak tailing, shortens assay duration and ensures repeatability of measurement results.
5. Sample injection pump: syringe-driven injection delivers high precision and good repeatability; injection volume can be adjusted according to sample measurement sequences.
6. High-efficiency Nafion tubing achieves effective water-vapor isolation without conventional dehydration membranes, better preventing gas-path blockage.
7. Optional 24-position auto-sampler enables unattended operation to save labor and time.
8. Optional solid-sample introduction module for measurement of solid and semi-solid samples.
9. The inner wall of the detector gas chamber is electroplated with infrared high-reflectivity metal to reduce infrared-light loss and achieve high detection accuracy.
10. Front-mounted combustion furnace for convenient operation and maintenance.
11. Detector adopts 24-bit A/D conversion technology for more stable data, lower noise, wider detection range and faster response.
12. Long-tube plug-grab halogen remover effectively mitigates halogen interference to the detector; manual halogen-removal-agent filling is not required.
13. Expandable total-nitrogen detector for total-nitrogen measurement.
14. Compliant with international standard ISO 8245.
Technical Parameters
1. Analysis modes: TC, TIC, NPOC, TOC
2. Digestion principle (TC): High-temperature catalytic oxidation, UV persulfate oxidation
3. Digestion principle (TIC): Acidification with 10% phosphoric acid plus aeration
4. Carrier gas: High-purity O₂ (99.999%)
5. Combustion temperature: 680-1000 °C adjustable
6. IC digestion temperature: 40 °C
7. Catalyst: CeO₂ or Pt/Al₂O₃
8. Measurement principle: NDIR (Non-Dispersive Infrared)
9. TOC measurement range: 0-30000 mg/L (automatic dilution for high-concentration samples)
10. Injection volume: 0.05-5 mL
11. TOC minimum detection limit: 10 ppb
12. Maximum salt tolerance: 85 g/L
13. TOC repeatability: 3%
14. Measurement accuracy: 5%
15. Control mode: PC-controlled
16. Analysis time: 2-4 minutes per parameter
17. Gas consumption: Approx. 150 mL/min
18. Operating environment: 0-40 °C, RH < 85%
19. Power supply: 220 ± 10 V AC, 50/60 Hz
20. Power rating: 1000 W
21. Overall dimensions: 340 (W) × 430 (D) × 540 (H) mm
22. Weight: 40 kg
Accessories
1. Solid TOC Module

Features
1) The solid combustion adopts a horizontal combustion furnace sample introduction design.
2) Uses electronic cooling for the sample boat.
3) Multiple sample introduction speeds are available to meet the needs of different samples.
4) Expandable for total nitrogen detection.
5) Complies with ISO 10694 Soil quality — Part 3: Chemical methods — Section 3.8: Determination of organic and total carbon after dry combustion (elementary analysis).
6) Complies with ISO 14855 Determination of the ultimate aerobic biodegradability of plastic materials under controlled composting conditions — Method by analysis of evolved carbon dioxide.
Technical Parameters
1. Analysis modes: TC, TIC, TOC; TN expandable
2. Digestion principle (TC): High temperature combustion oxidation
3. Digestion principle (TIC): Phosphoric acid acidification
4. Carrier gas: High purity O₂ (99.999%)
5. Combustion temperature: 680 1300℃ adjustable
6. Sample mass: 10-200 mg
7. Minimum detection limit: 50 ppb
8. Measurement principle: NDIR
9. Measurement range: 0-30000 ppm
10. Measured matrix: solids; liquids expandable
11. Solid auto sampler capacity: 24 positions
12. Solid sample analysis time: < 10 min
13. Gas consumption: Approx. 150 mL/min
14. Power rating: 1000 W
15. Power supply: 220 ± 10 V AC, 50/60 Hz
16. Weight: 30 kg
2. Software

l Strong compatibility with single-chip microcomputer software and low requirements for computer hardware.
Operating system: Win10 (64-bit)
1) Hardware requirements: SSD ≥ 256 GB, i3 or higher-grade processor, RAM ≥ 8 GB, display resolution ≥ 1366 × 768.
2) Multi-level user permission management with password login, compliant with FDA 21 CFR Part 11 requirements.
3) Supports query of historical operation records, meeting the requirements for audit trail and data traceability.
4) Multiple measurement modes including TC, TIC, TOC and NPOC are available; TN/TS can be expanded.
5) The software displays multiple measurement results, average values and RSD values.
6) Real-time CO₂ integration curve can be visualized for intuitive monitoring of instrument operating status.
7) Historical records can be retrieved by test date, with well-organized historical files and data.
8) Supports export to Excel or PDF formats. Single-sample or multi-sample export options are available to accommodate diverse user needs.
3. LAS24 Automatic Sampler

Features
1) Features a rotatable 24-position sampling vial design, meeting the needs of routine daily testing.
2) Stable and reliable operation with no need for special routine maintenance and low maintenance costs.
3) Equipped with RS485 online communication function to achieve synchronous interlocking with different types of analyzers.
4) Optional dual-head sampling needle allows integrated purging and sampling for NPOC analysis.
Technical Parameters
Sampling vial positions | 24 positions |
Sampling vial volume | 60 mL |
Operating temperature | 0-40 °C |
Power rating | 60 W |
Power supply | 220 ± 10 V AC, 50/60 Hz |
Operating environment | 0-40 °C, RH < 85% |
Overall dimensions | 300 × 260 × 380 mm |
Weight | 5 kg |