capillary Viscometer
  • ASTM D4603 Inherent Viscosity Of PET By Glass Capillary Viscometer

    ASTM D4603 Inherent Viscosity Of PET By Glass Capillary Viscometer

    The inherent viscosity is determined by measuring the flow time of a solution of known polymer concentration and the flow time of the pure solvent in a capillary viscometer at a fixed temperature. The inherent viscosity value is calculated from the flow time values

    Send Email Details
  • ASTM D2170 Viscosity Of Asphalts By Vacuum Capillary Viscometer

    ASTM D2170 Viscosity Of Asphalts By Vacuum Capillary Viscometer

    the kinematic viscosity characterizes flow behavior. the method is used to determine the consistency of bitumen as one element in establishing the uniformity of shipments or sources of supply. the specifications are usually at temperature of 60 and 135℃.

    Send Email Details
  • ASTM D2171 Viscosity of Asphalts by Vacuum Capillary Viscometer

    ASTM D2171 Viscosity of Asphalts by Vacuum Capillary Viscometer

    1

    Send Email Details
  • ASTM D2171 Apparatus for Viscosity of Asphalts

    ASTM D2171 Apparatus for Viscosity of Asphalts

    ​KN-2171 Apparatus for Viscosity of Asphalts conforms to ASTM D2171 Standard Test Method for Viscosity of Asphalts by Vacuum Capillary Viscometer. The viscosity at 60℃ characterizes flow behavior and may be used for specification requirements for cutbacks and asphalt binders. This time is measured for a fixed volume of the liquid to be drawn up through a capillary tube by means of vacuum, under closely controlled conditions of vacuum and temperature. The viscosity in Pascal-seconds is calculated by multiplying the flow time in seconds by the viscometer calibration factor.

    Send Email Details
  • ASTM D446 Full Automatic Viscometer Cleanser

    ASTM D446 Full Automatic Viscometer Cleanser

    This Ultrasonic capillary viscometer cleaner is used for cleaning the capillary viscometers,such as opaque, routine, Ubbelohde, or Pinkevitch viscometers.

    Send Email Details
  • Routine Viscometer

    Routine Viscometer

    The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170. Minimum sample volume is 12 mL. Minimum bath depth is 230 mm (9 in). Special constant viscometers are available at additional cost. This is a calibrated viscometer which include a certificate of calibration and instruction sheet. Uncalibrated viscometers are also available. Holders are sold separately.

    Send Email Details
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy